It should be noted that when geothermal heating is used, the surface temperature should not exceed 28 ℃, and the water pipe temperature should not exceed 45 ℃. If the temperature is exceeded, the service life and service cycle of the floor will be affected

1. Heating should be gradual during initial use

when using geothermal floor, consumers must pay attention to heating the floor and floor step by step. During installation, the ground temperature should be maintained at about 18 ℃. Before installation, the cement floor should be gradually heated up, increasing by 5 ℃ every day until it reaches the standard of about 18 ℃. This temperature should be maintained for the first three days after installation. The temperature can be increased as needed after three days, and it can only be increased by 5 ℃ every day

when using geothermal heating for the first time, pay attention to heating slowly. When it is used for the first time, it should be gradually heated up in the first three days of heating: the water temperature is 18 ℃ on the first day, 25 ℃ on the second day, 30 ℃ on the third day, and can rise to the normal temperature on the fourth day, that is, the water temperature is 45 ℃, and the surface temperature is 28 ℃ ~ 30 ℃. Do not heat up too fast. If it is too fast, the floor may crack and distort due to expansion

when the geothermal heating system is used again after a long time, it should also be heated strictly according to the heating program as it was used for the first time

2. The surface temperature should not be too high

it should be noted that when geothermal heating is used, the surface temperature should not exceed 28 ℃, and the water pipe temperature should not exceed 45 ℃. If the temperature is exceeded, the service life and service cycle of the floor will be affected. For ordinary families, when the room temperature reaches about 22 ℃ in winter, it is already very comfortable. If the temperature rises normally, it will not affect the use of geothermal floors

3. Close the geothermal system and pay attention to gradual cooling

as the season goes on, when the weather warms up and the geothermal system heating is no longer needed indoors, it should be noted that there is also a process to turn off the geothermal system, and the cooling process of the floor should also be gradual, not sudden drop. If the cooling speed is too fast, it will also affect the service life of the floor

4. Humidification can be considered when the room is too dry

in winter, the climate is dry, coupled with the use of geothermal heating, and the floor is easy to dry and crack under the condition of high temperature for a long time. At this time, it is necessary for the owner to humidify the room to prevent the floor from drying and deformation

when decorating, pay attention not to drill holes and nails on the ground, so as not to leak the geothermal pipeline, which will cause the geothermal system to run away and the floor to be discarded. In addition, because the floor surface is a heat dissipation surface, try not to make fixed decorative parts or place legless furniture on the floor, and it is not suitable to add a platform, so as not to affect the flow of hot air, resulting in poor room heating effect

because the surface temperature of the floor is relatively high, it is best not to place glassware and porcelain containing water directly on the ground in winter in rooms using geothermal heating system, so as to avoid the cracking of utensils due to uneven heating, thermal expansion and contraction, and “ Water overflows the golden mountain &rdquo

geothermal floor has become a fashionable decoration in home decoration, but we must pay more attention to details when purchasing and paving, especially in terms of maintenance, the requirements of geothermal floor are higher